-
Dam Rose posted an update 6 months, 1 week ago
Real-time object identification and classification are essential in many microfluidic applications especially in the droplet microfluidics. This paper discusses the application of convolutional neural networks to detect the merged microdroplet in the flow field and classify them in an on-the-go manner based on the extent of mixing. The droplets are generated in PMMA microfluidic devices employing flow-focusing and cross-flow configurations. The visualization of binary coalescence of droplets is performed by a CCD camera attached to a microscope, and the sequence of images is recorded. Different real-time object localization and classification networks such as You Only Look Once and Singleshot Multibox Detector are deployed for droplet detection and characterization. A custom dataset to train these deep neural networks to detect and classify is created from the captured images and labeled manually. The merged droplets are segregated based on the degree of mixing into three categories low mixing, intermediate mixing, and high mixing. The trained model is tested against images taken at different ambient conditions, droplet shapes, droplet sizes, and binary-fluid combinations, which indeed exhibited high accuracy and precision in predictions. In addition, it is demonstrated that these schemes are efficient in localization of coalesced binary droplets from the recorded video or image and classify them based on grade of mixing irrespective of experimental conditions in real time.Freestanding lipid bilayers are one of the most used model systems to mimic biological cell membranes. To form an unsupported bilayer, we employ two aqueous fingers in a microfluidic chip surrounded by an oily phase that contains lipids. Upon pushing two aqueous fingers forward, their interface becomes decorated with a lipid monolayer and eventually zip to form a bilayer when the monolayers have nanoscopic contact with each other. Using this straightforward approach, the quick and easy bilayer formation is facilitated by oil draining into the microfluidic device material consisting of polydimethylsiloxane. However, the oil drainage limits the lifetime of a bilayer to about 1 h. We demonstrate that this drainage can be managed, resulting in superior bilayer stability and an increased lifetime of several hours when using a pressure-controlled system. Applying different pressures to the aqueous fingers in the microfluidic chip, the formed bilayer can even be bent to a desired curvature. Extracting the contact angle and the resulting curvature of the bilayer region, for a given applied pressure difference, both the bilayer tension and the surface tension of each lipid monolayer can be derived from a single experiment using the Young Laplace pressure equation.Micropipette aspiration, optical tweezers, rheometry, or ecktacytometry have been used to study the shape recovery of healthy human Red Blood Cells (RBCs) and measure associated relaxation times of the order of 100-300 ms. These measurements are in good agreement with the Kelvin-Voigt model, which describes the cell as a visco-elastic material, predicting that its relaxation time only depends on cell intrinsic properties. However, such mechanical solicitation techniques are far from being relevant regarding RBC solicitation in vivo. In this paper, we report for the first time the existence of two different behaviors of the RBC shape recovery while flowing out of a microfluidic constricted channel. The calculation of the viscous stress corresponding to the frontier between the two recovery modes confirms that the RBC resistance to shear μ is the elastic property dominating the transition between the two recovery behaviors. We also quantified associated recovery times τ r and report values as low as 4 ms-which is almost two decades smaller than the typical RBC relaxation time-at high viscosity and flow velocity of the carrier fluid. Although we cannot talk about relaxation time because the cell is never at rest, we believe that the measured shape recovery time arises from the coupling of the cell intrinsic deformability and the hydrodynamic stress. Depending on the flow conditions, the cell mechanics becomes dominant and drives the shape recovery process, allowing the measurement of recovery times of the same order of magnitude than relaxation times previously published. Finally, we demonstrated that the measurement of the shape recovery time can be used to distinguish Plasmodium falciparum (causing malaria) infected RBCs from healthy RBCs.A compact, fully-automatic blood-typing test device is developed. The device conducts sequential processes of whole-blood dilution, homogenization, and reaction with reagents. learn more The lab-on-a-chip device can detect the weakest reaction between red blood cells (RBCs) and reagents even without using optics such as a camera and detector. This high sensitivity is achieved by implementing 50-μm-thick reaction chambers in which a clear contrast between the RBC agglutinations and non-reacted RBCs can be obtained. The dilution and the homogenization are enhanced by injecting bubbles into the microchannel so that the test result can be obtained 5 min after the test start. With an assumption that the device will be used by medical staffs, the device is designed to require minimum operation for the users, namely, loading whole blood, starting pumps, and looking inside the reaction chambers by their eyes to observe the test result. As the device is applicable to the cross-matching test by mixing RBCs with serum instead of the reagents, it is expected that the device provides not only the quick blood-typing but also a safer and quicker blood transfusion in emergency rooms.The blood hemoproteins, albumin, γ-globulin, and fibrinogen, serve as biomarkers for a variety of human diseases, including kidney and hepatorenal syndromes. Therefore, there is a need to quickly and accurately measure their concentrations in blood. Herein, nucleic acid aptamers demonstrating high affinity and specificity toward these hemoproteins were selected via systematic evolution of ligands by exponential enrichment, and their ability to capture their protein targets was assessed with sodium dodecyl sulfate-polyacrylamide gel electrophoresis followed by a tetramethyl benzidine assay. The limits of detection for the hemoproteins were all around 10-3 μM, and dissociation constant values of 131, 639, and 29nM were obtained; capture rates were measured to be 66%, 71%, and 61%, which is likely to be suitable for clinical diagnostics. Furthermore, a multi-layer microfluidic disk system featuring hemoprotein-specific aptamers for depleting hemoproteins was demonstrated. It could be a promising approach to use aptamers to replace conventional antibodies.