• Hardin Kyed posted an update 6 months, 2 weeks ago

    adaptive radiotherapy.

    The commissioning results and clinical QA results show that the uRT-linac 506c platform exhibits good and stable performance in mechanical and dosimetric accuracy. The integrated CT system provides an efficient workflow for image guidance with submillimeter localization precision, and will be a good starting point to proceed advanced adaptive radiotherapy.

    This study aimed to assess dosimetric indices of RapidPlan model-based plans for different energies (6, 8, 10, and 15MV; 6- and 10-MV flattening filter-free), multileaf collimator (MLC) types (Millennium 120, High Definition 120, dual-layer MLC), and disease sites (head and neck, pancreatic, and rectal cancer) and compare these parameters with those of clinical plans.

    RapidPlan models in the Eclipse version 15.6 were used with the data of 28, 42, and 20 patients with head and neck, pancreatic, and rectal cancer, respectively. RapidPlan models of head and neck, pancreatic, and rectal cancer were created for TrueBeam STx (High Definition 120) with 6MV, TrueBeam STx with 10-MV flattening filter-free, and Clinac iX (Millennium 120) with 15MV, respectively. The models were used to create volumetric-modulated arc therapy plans for a 10-patient test dataset using all energy and MLC types at all disease sites. The Holm test was used to compare multiple dosimetric indices in different treatment machines and energy types.

    The dosimetric indices for planning target volume and organs at risk in RapidPlan model-based plans were comparable to those in the clinical plan. Furthermore, no dose difference was observed among the RapidPlan models. The variability among RapidPlan models was consistent regardless of the treatment machines, MLC types, and energy.

    Dosimetric indices of RapidPlan model-based plans appear to be comparable to the ones based on clinical plans regardless of energies, MLC types, and disease sites. The results suggest that the RapidPlan model can generate treatment plans independent of the type of treatment machine.

    Dosimetric indices of RapidPlan model-based plans appear to be comparable to the ones based on clinical plans regardless of energies, MLC types, and disease sites. The results suggest that the RapidPlan model can generate treatment plans independent of the type of treatment machine.

    In this study, 4-Hz log files were evaluated with an independent secondary Monte Carlo dose calculation algorithm to reduce the workload for patient-specific quality assurance (QA) in clinical routine.

    A total of 30 randomly selected clinical prostate VMAT plans were included. The used treatment planning system (TPS) was Monaco (Elekta, Crawley), and the secondary dose calculation software was SciMoCa (Scientific-RT, Munich). Monaco and SciMoCa work with a Monte Carlo algorithm. A plausibility check of Monaco and SciMoCa was performed using an ionization chamber in the BodyPhantom (BP). First, the original Monaco RT plans were verified with SciMoCa (pretreatment QA). Second, the corresponding 4-Hz log files were converted into RT log file plans and sent to SciMoCa as on-treatment QA. MLC shift errors were introduced for one prostate plan to determine the sensitivity of on-treatment QA. For pretreatment and on-treatment QA, a gamma analysis (2%/1mm/20%) was performed and dosimetric values of PTV and OARs ws and SciMoCa can replace labor-intensive phantom-based measurements as patient-specific QA.”Escaping from flatland”, by increasing the saturation level and three-dimensionality of drug-like compounds, can enhance their potency, selectivity and pharmacokinetic profile. One approach that has attracted considerable recent attention is the bioisosteric replacement of aromatic rings, internal alkynes and tert-butyl groups with bicyclopentane (BCP) units. click here While functionalisation of the tertiary bridgehead positions of BCP derivatives is well-documented, functionalisation of the three concyclic secondary bridge positions remains an emerging field. The unique properties of the BCP core present considerable synthetic challenges to the development of such transformations. However, the bridge positions provide novel vectors for drug discovery and applications in materials science, providing entry to novel chemical and intellectual property space. This Minireview aims to consolidate the major advances in the field, serving as a useful reference to guide further work that is expected in the coming years.

    Disturbances in body image can have an impact on sexual health and are prevalent in women of reproductive age. Although body image is important, the definition of this concept is inconsistent across the disciplines of nursing, medicine, and psychology. Use of a consistent definition in clinical practice and research could lead to a more comprehensive understanding of disturbances in body image, thereby advancing research-based knowledge and clinical practice. The purpose of this concept development was to advance the concept of body image as it relates to sexual health among women of reproductive age from the perspectives of 3 disciplines with a strong focus on body image nursing, medicine, and psychology.

    Strategies for concept development as described by Rodgers provided the basis for this work. The process includes a search, review, and synthesis of the literature surrounding the concept of interest.

    Seventy-one articles, mostly qualitative and quantitative descriptive, were included and used to develop the concept. Body image related to sexual health in women of reproductive age is a multifaceted concept that is composed of an emotional and behavioral response to one’s perceived appearance, sexuality, and degree of femininity. An individual’s body image is influenced by sociocultural identities, race, ethnicity, and health status. It has both physical and psychological impact on health outcomes.

    This interprofessional and comprehensive definition of body image should enhance understanding, assessment, and management of body image disturbances, thus bridging disciplines and enhancing interprofessional research and practice.

    This interprofessional and comprehensive definition of body image should enhance understanding, assessment, and management of body image disturbances, thus bridging disciplines and enhancing interprofessional research and practice.

All content contained on CatsWannaBeCats.Com, unless otherwise acknowledged,is the property of CatsWannaBeCats.Com and subject to copyright.

CONTACT US

We're not around right now. But you can send us an email and we'll get back to you, asap.

Sending

Log in with your credentials

or    

Forgot your details?

Create Account